Siemens SQM10 / 11 Actuator

Siemens SQM10 / 11 Actuator

  • $3,050.64


SQM10 Actuators for air dampers and control valves of oil burners. Standard Actuators with a Diameter of drive shaft 10mm.

 

High Quantities and less-common models may take an additional 10 days for shipment. Contact us via phone or Email to request more information on availability. 

 

Available Models:

All Models have 7"/lbs Nominal Torque and 5 Switches except where specified

  • SQM10.15502 - Counter Clockwise, 14 second running time for 90° at 50 Hz, 110 V, 5 Auxiliary Switches, refer to Wiring Diagram 1
  • SQM10.15561 - Counter Clockwise, 14 second running time for 90° at 50 Hz, 110 V, 5 Auxiliary Switches, refer to Wiring Diagram 2
  • SQM10.15562 - Counter Clockwise, 14 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 2
  • SQM10.16102 Counter Clockwise, 29 second running time for 90° at 50 Hz, 220 V, 1 Auxiliary Switches, refer to Wiring Diagram 1
  • SQM10.16502 - Counter Clockwise, 29 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 1 
  • SQM10.16501 - Counter Clockwise, 29 second running time for 90° at 50 Hz, 110 V, 5 Auxiliary Switches, refer to Wiring Diagram 1 
  • SQM10.16561 -Counter Clockwise, 29 second running time for 90° at 50 Hz, 110 V, 5 Auxiliary Switches, refer to Wiring Diagram 2
  • SQM10.16562 - Counter Clockwise, 29 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 2
  • SQM10.17502 - Counter Clockwise, 70 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 1
  • SQM11.15502 - Clockwise, 14 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 1 
  • SQM11.15562 Clockwise, 14 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 2
  • SQM11.16502 - Clockwise, 29 second running time for 90° at 50 Hz, 220 V, 5 Auxiliary Switches, refer to Wiring Diagram 1 
  • SQM11.16501 - Clockwise, 29 second running time for 90° at 50 Hz, 110 V, 5 Auxiliary Switches, refer to Wiring Diagram 1 

 